CJ19 Contactor
Electric ratings: AC380V, AC50/60Hz; Application: put a low voltage parallel connected capacitor in operation or switch it off in a low voltage reactive power compensation device. The contactor is equipped with a surge suppressor, which can effectively reduce the surge current passing through the capacitor at switching on and suppress the over-voltage at switching off. Standard: IEC60947-4-1. |
|
|
NC1-N Contactor, rever- sing& change-over type
Electrical ratings: AC50/60HZ, 660V, 95A; Application: for reversing control of motor and the mechanical interlock ensures operation reliability for contactor changeover of the two reversing contactors; Standard: IEC60947-4-1 |
|
|
NC1 Contactor
Electric ratings: AC50/60Hz, 660V, up to 95A; Application: for remote making & breaking circuits; protection of circuit from over-load assembled with thermal over-load relay; frequent start-up and control of AC contactor; Standard: IEC/EN 60947-4-1. |
|
|
NC2-N Contactor, rever- sing& change-over type
Electric ratings; AC50/60Hz, up to 1000V, up to 630A; Application: for reversing control of motor and the mechanical interlock ensures operation reliability for contactor changeover of the two reversing contactors; Standard: IEC/EN 60947-4-1. |
|
|
NC2 Contactor
Electric ratings; AC50/60Hz, up to 1000V, up to 630A; Application: for remote making & breaking circuits; protection of circuit from over-load assembled with thermal over-load relay; Standard: IEC/EN 60947-4-1. |
|
|
NC6 Contactor
Electric ratings: AC50/60Hz, up to 690V, up to 9A; Application: for remote making and breaking of circuit; protection of circuit from over-load assembled with proper thermal relay; Standard: IEC/EN 60947-4-1 |
|
|
NC8
NC8 series AC contactor is applied to circuits with AC current frequency of 50 Hz or 60 Hz, rated operational voltage up to 690 V and rated operational current up to 100 A. It is used for remote making & breaking circuits, and can also be used with proper thermal overload relay together as an electromagnetic starter to protect circuits from overload.This product conforms to standards IEC/EN 60947-4-1. |
|
|
NC9 Vacuun Contactor
Electrical ratings: AC50Hz, up to 1140V, up to 1000A; Application: for remote making and breaking circuit, assembled with thermal over-load relay or some other protective devices to be vacuum starter; Standard: IEC/EN 60947-4-1 |
|
|
NCK3 Denifite Purpose Contactor
Electric ratings: AC50/60Hz, 380V, 40A; Application: for making and breaking of the circuit under air-conditioning application; Standard: UL508 |